Manual-16
SRM 66 Slave ActiveX control
Control Name: Via10SRMSlaveX
Description: Automatic control of an SRM 66 in SLAVE mode. See RaneNote 138 for more details on parameters.
Design Time Parameters:
Addr Via 10’s IP Address
Port 0 = RS-485, 1 = RS-232
Remote_1_Enabled 0 = Disabled, -1 = Enabled
Remote_2_Enabled 0 = Disabled, -1 = Enabled
Remote_3_Enabled 0 = Disabled, -1 = Enabled
Remote_4_Enabled 0 = Disabled, -1 = Enabled
Remote_5_Enabled 0 = Disabled, -1 = Enabled
Remote_6_Enabled 0 = Disabled, -1 = Enabled
Remote_7_Enabled 0 = Disabled, -1 = Enabled
Runtime Parameters:
ErrorCount 0
Remote_1 Value of SR 1L Address 1 (0 – 31)
Remote_2 Value of SR 1L Address 2 (0 – 31)
Remote_3 Value of SR 1L Address 3 (0 – 31)
Remote_4 Value of SR 1L Address 4 (0 – 31)
Remote_5 Value of SR 1L Address 5 (0 – 31)
Remote_6 Value of SR 1L Address 6 (0 – 31)
Remote_7 Value of SR 1L Address 7 (0 – 31)
Key Methods:
DoConnect Initialize a connection with the Via 10. This automatically sets the proper baud and parity
rates for SRM 66 use.
SetMem Memory change for all slaved SRM 66s
Events: OnError An error occurred talking to the Via 10
Initialization: DoConnect must be called to initialize a connection to the Via 10
RW 232 ActiveX control. Required for all RW 232 communications.
Control Name: Via10RW232X
Description: Communication manager required for all RW 232 based controls
Design Time Parameters:
Addr Via 10’s IP Address
Port 0 = RS-232, 1 = RS-485
Runtime Parameters:
Timeouts A count of Timeouts talking to units
Retrys Via 10 packets lost
Key Methods:
DoConnect Initialize a connection with the Via 10. This automatically sets the proper baud and parity
rates for RW 232 use.
Events: OnError An error occurred talking to the Via 10
Initialization: DoConnect Must be called to initialize a connection to the Via 10