Device Control Language
Data Structures
Abbreviations used: Definition:
$: signifies hexadecimal number
ADDR: Device Address
CHNUM: Channel Number code
COMSTAT: Communications Status code
DCL: Device Control Language
DT: Device-Type code (predefined)
ID: Manufacturer’s ID code (predefined)
MEMNUM: Memory Number code
OPSTAT: Operational Status code
SPL: Stored Parameter List (product dependent)
ECM 64 Stored Parameter List (SPL):
System Parameters:
Index Hex Name / System ParametersEncoding Method
0 $00 Meter Display 0-7 (byte) 0 = Mic Mix
1 = Line In
2 = Aux In
3 = Hybrid Rx
4 = Out 1
5 = Out 2
6 = Out 3
7 = Hybrid Tx
1 $01 Auto Answer Ring Count 0-9 (byte) 0 = Auto Answer Off;
1 = Answer after 1st ring
2 $02 Auto Disconnect 1/0 (byte) 1 = On, 0 = Off
3 $03 Privacy 1/0 (byte) 1 = On, 0 = Off
4 $04 Mute 1/0 (byte) 1 = On, 0 = Off
5 $05 (Reserved) 1/0 (byte) 1 = On, 0 = Off
6 $06 AEC 3 kHz 1/0 (byte) 1 = On, 0 = Off
7 $07 AEC Mute 1/0 (byte) 1 = On, 0 = Off
8 $08 AEC In Mic Mix 1/0 (byte) 1 = On, 0 = Off
9 $09 AEC In Line 1/0 (byte) 1 = On, 0 = Off
10 $0A AEC In Aux 1/0 (byte) 1 = On, 0 = Off
11 $0B AEC Ref. (Mix In/Out1/Ext) 0/1/2 (byte) 0 = Mix In, 1 = Out 1, 2 = Ext.
12 $0C AEC Ref. Line In 1/0 (byte) 1 = On, 0 = Off
13 $0D AEC Ref. Aux In 1/0 (byte) 1 = On, 0 = Off
14-20 $0E - $14 Reserved (Fill with 0s) 0 (byte) 0
Inputs Parameters:
Index Hex Name / System ParametersEncoding Method
21 $15 Mic 1 (Mute)* 1/0 (byte) 1 = Mute
22 $16 Mic 2 (Mute)* 1/0 (byte) 1 = Mute
23 $17 Mic 3 (Mute)* 1/0 (byte) 1 = Mute
24 $18 Mic 4 (Mute)* 1/0 (byte) 1 = Mute
25 $19 Line In (Mute)* 1/0 (byte) 1 = Mute
26 $1A Aux In (Mute)* 1/0 (byte) 1 = Mute
27 $1B Mic 1 Level 0 to 31 (byte) -15 to +16 dB
28 $1C Mic 2 Level 0 to 31 (byte) -15 to +16 dB
29 $1D Mic 3 Level 0 to 31 (byte) -15 to +16 dB
30 $1E Mic 4 Level 0 to 31 (byte) -15 to +16 dB
31 $1F Line In Level 0 to 31 (byte) -15 to +16 dB
32 $20 Aux In Level 0 to 31 (byte) -15 to +16 dB
* Only these function are recalled when setting CHNUM to 1 or 2.