25. What to do if... ?
Fault Possible cause / solution
... the RolloTron Standard DuoFern no longer reacts in
the morning at the configured switching time?
The electronic system switched off the drive after closing the roller
shutters because the deflection roller stopped turning.
This is the case if:
a) The [Down] button was pressed for an excessive period of time
during the configuration process for the lower end point. The roller
shutter slats are closed, but the belt continued to wind and is no
longer tight on the deflection roller.
b) The lower end point is displaced due to elongation of the belt.
The belt may never be slack.
Reconfigure the lower end point (see page 23) and ensure that
the belt remains tight to the deflection roller.
In doing so, the deflection roller must turn evenly.
... the RolloTron Standard DuoFern fails to react properly
either manually or automatically?
a)
The RolloTron Standard DuoFern is no longer ready for operation.
Carry out a hardware reset in accordance with page 35.
b) If the RolloTron Standard DuoFern still fails to react after the
hardware reset, carry out a software reset in accordance with the
instructions on page 35. Subsequently test the RolloTron
Standard DuoFern with the default factory settings.
i

Bekijk gratis de handleiding van Rademacher RolloTron Standard DuoFern 1400, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkRademacher
ModelRolloTron Standard DuoFern 1400
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3743 MB

Caratteristiche Prodotto

Kleur van het productWit
Ingebouwd displayJa
Stroomverbruik (in standby)0.6 W
Maximale gewichtscapaciteit45 kg
Frequentie434.5 MHz