Factory parameters preset
With the PRESET operation, the TermoPID control unit can be reconfigured with
the default parameters (factory data).
To perform the PRESET, proceed as follows:
- With the termopid disabled. press ▼.
- Power the board.
- When the display shows “prs” release the key.
- Cut-out the power to the board.
The factory data (default) is the following:
F03 - °C
P – 1,0
I – 0,01
D – 2,0
F04 - 0
Alarms
In the case of a sensor failure, on the display the caption A1 is shown: the
adjustment and programming outputs are disabled.
Termopid Setting and Functioning model CAROLA
With this TERMOPID model, the set pont temperature adjustment is through the
position of the micro switch as shown below.