Promise Technology VESS A3340S handleiding
Handleiding
Je bekijkt pagina 174 van 243

163
Managing with CLIVess A3340s / Vess A3340d / Vess A3340 PoE
factorydefaults
Usage
factorydefaults -a <action> -t <type>
Summary
The factorydefaults command restores factory default settings.
Options
-a <action> Species the action to perform.
restore Restore the factory default settings.
-t <type> Species the type of settings to restore.
all All settings.
allfw All rmware settings.
allsw Subsystems only. All software settings.
Following are individual Firmware settings:
bga Background activity settings.
ctrl Controller settings.
encl Enclosure settings, including temperature thresholds.
netiscsi Subsystems only. Network settings of iSCSI ports.
netmgmt Subsystems only. Network settings of management ports.
phydrv Physical drive settings.
subsys Subsystem settings.