Type
of
Gas
BURNER:
Rapid
(large)
Semi-rapid
(medium)
Auxiliary
(small)
Natural Gas
THERMAL POWER (kW):
3.0
1.75
1.0
INJECTOR DIAMETER
(mm):
1.30
1.00
0.78
LPG Gas
THERMAL POWER (kW):
3.0
1.75
1.0
FLOW RATE (g/h):
219
127
73
INJECTOR DIAMETER
(mm):
0.87
0.66
0.50
Natural gas category: I2H (20) / I2E+
LPG (Liquefied Petroleum Gas) gas category: I3+(28-30/37)
COMMISSIONING
When the hob has been fully installed it will be necessary to check the
minimum flame setting. To do this, follow the procedure below.
Turn the gas tap to the MAX position and ignite.
Set the gas tap to the MIN flame position then turn the control knob from
to several times. If the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to .
Remove the control knob.
To adjust, use a thin bladed screwdriver (not
supplied) and turn the adjustment screw
until the flame is steady and does not
extinguish, when the knob is turned from
to .
Repeat this procedure for all burners.
Gas specification
10
Total heat input : 7.5kW(546g/h)