Proficare PC-GKH3118 handleiding
Handleiding
Je bekijkt pagina 19 van 90

PC-GKH3118_IM 01.09.23
19
Overheat Protection
The appliance features an overheat protection mechanism
causing the appliance to switch off automatically in case of
overheating.
1. Then pull the mains plug out of the socket.
2. Let the appliance cool down for approx. 10 minutes
before using it again.
- If the overheat protection mechanism causes the appli-
ance to switch off again after a short period, this might in-
dicate a defect. Switch off the appliance and disconnect
it from the mains. Have the appliance checked by your
dealer or our customer service.
Cleaning
WARNING:
• Always unplug the appliance from the mains before
cleaning and wait until the appliance has cooled down.
• Never immerse the appliance in water to clean it. This
may lead to electrical shock or re.
CAUTION:
• Do not use wire brushes or other abrasive materials.
• Do not use caustic or scouring agents.
• Wipe away dust with a dry cloth.
• Flecks can be removed with a suitably damp cloth.
Dust on the Protective Grille from the Air Outlet
If dust has collected on the protective grille, this can cause
overheating.
• Remove the dust by careful brushing.
or
• Use the upholstery nozzle of your vacuum cleaner to
remove the dust.
Storage
• When used as a stand-alone appliance, we recommend
storing the appliance in its original packaging if it is not
going to be used for a long period of time.
• Let the appliance cool down before putting it away!
• Always store the appliance out of the reach of children in
a well-ventilated and dry place.
Technical Data
Model:...............................................................PC-GKH 3118
Power supply:............................................. 230 V~, 50 / 60 Hz
Power consumption: ...........................................750 / 1500 W
Protection class: .....................................................................
Net weight: ....................................................... approx. 5.2 kg
The right to make technical and design modications in
the course of continuous product development remains
reserved.
This appliance has been tested according to all applicable,
current CE directives and built according to the latest safety
regulations.
Product Data Sheet
Model identier PC-GKH 3118
Item Symbol Value Unit Item Unit
Heat output
Type of heat input, for electric storage local space heaters only
Nominal heat output P
nom
1.50 kW manual heat charge control, with integrated thermostat no
Minimum heat output
(indicative)
P
min
0.75 kW
manual heat charge control with room and / or
outdoor temperature feedback
no
Maximum continuous
heat output
P
max, c
1.50 kW
electronic heat charge control with room and / or
outdoor temperature feedback
no
Auxiliary electricity consumption fan assisted heat output no
At nominal heat
output
el
max
0.000 kW Type of heat output / room temperature control
At minimum heat
output
el
min
0.000 kW single stage heat output and no room temperature control no
In standby mode el
SB
0.00141 kW Two or more manual stages, no room temperature control no
with mechanic thermostat room temperature control no
with electronic room temperature control no