Proel AE604 handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 35 van 48
35
6. EVENTS, FAULTS and TROUBLESHOOTING TABLE
ID EVENT LOG LOG Detail POP-UP Description Action
1 SYS System power ON System power ON
Startup successful
System on, the event is recorded at the end of the
start-up sequence.
2 SYS System old rtc time System time setup event
Log previous rtc time
Edit system date and time, the event is recorded with
the date and time prior to the change.
3 SYS System new rtc time System time setup event
Log new rtc time
Edit system date and time, the event is recorded with
the date and time after the change.
4 SYS System logs deleted All system logs
deleted by user
Deletion of system events by user command. All LOG
have been deleted.
5 SYS Auth access level 3 Authentication event
Current access level 3
Authentication to access level 3
6 VOICE
ALARM
Local fire mike START Alarm message START
Local fire mike
Local fire microphone Launch of a "spoken" alarm message from the
integrated microphone.
7 VOICE
ALARM
Local fire mike STOP Alarm message STOP
Local fire mike
Stop of a "spoken" alarm message from the
integrated microphone.
8 VOICE
ALARM
Remote fire mike START Alarm message START
Remote fire mike
Remote fire mic Launch of a “spoken” alarm message from remote
alarm microphone connected via BUS
9 VOICE
ALARM
Remote fire mike STOP Alarm message STOP
Remote fire mike
Stop of a “spoken” alarm message from remote alarm
microphone connected via BUS
10 VOICE
ALARM
Eth alarm talk START Alarm message START
From Ethernet
ETH Alarm talk Launch of a “spoken” alarm message from ethernet
microphone workstation
11 VOICE
ALARM
Eth alarm talk STOP Alarm message STOP
From Ethernet
Stop of a “spoken” alarm message from ethernet
microphone workstation
12 VOICE
ALARM
EVAC message START EVAC message START
From uSD Player
Evac Message
playback
Start playback of evacuation message from uSD.
13 VOICE
ALARM
EVAC message STOP EVAC message STOP
From uSD Player
Stop playback of evacuation message from uSD.
14 VOICE
ALARM
ALARM message START ALARM message START
From uSD Player
Alarm Message
playback
Start playback of alarm message from uSD.
15 VOICE
ALARM
ALARM message STOP ALARM message STOP
From uSD Player
Stop playback of alarm message from uSD.
16 FAULT
WARNING
Line NOT calibrated Line calibration FAULT
Line is not calibrated
No line calibration Error: Line not calibrated Calibrate speakers lines
17 Line calibrated Line calibration RESUME
Line is now calibrated
The event is stored at the end of the line calibration
procedure with positive outcome.
18 FAULT
WARNING
Amplifier FAULT Amplifier # FAULT
Amplifier is unusable
Amplifier fault Amplifier fault ( number displayed ) :
Device:
1 Amplifier 1
2 Amplifier 2
Detail:
1 Internal fault.
2 Overload.
3 Overheating.
4 Cooling fan fault.
Based on the fault type you need to
make the following actions:
Internal fault: consult the technical
service
Overload: check the speakers line
Overheating: check if there is
enough ventilation
Colling fan fault: consult the
technical service
19 Amplifier RESUME Amplifier # RESUME
Amplifier is OK
Amplifier restored ( number displayed ):
Device:
1 Amplifier 1
2 Amplifier 2
Detail:
1 Internal fault.
2 Overload.
3 Overheating.
4 Coolinjg fan fault.
20 FAULT
WARNING
Speaker line FAULT Speaker line # FAULT
See doc. for detail
Speaker line fault Impedence fault of the speakers line:
Device:
1 Speaker Line 1-A
2 Speaker Line 1-B
3 Speaker Line 2-A
4 Speaker Line 2-B
5 Speaker Line 3-A
6 Speaker Line 3-B
7 Speaker Line 4-A
8 Speaker Line 5-B
Detail:
1 Ground shorted.
2 Load not detected.
2 Underload.
3 Overload.
4 Impedence out of range.
5 Short-circuit.
Check speakers lines
21 Speaker line RESUME Speaker line # RESUME
See doc. for detail
Impedence of the speakers line fault restored :
Device:
1 Speaker Line 1-A
2 Speaker Line 1-B
3 Speaker Line 2-A
4 Speaker Line 2-B
5 Speaker Line 3-A
6 Speaker Line 3-B
7 Speaker Line 4-A
8 Speaker Line 5-B
Detail:
1 Ground shorted.
2 Loss not detected.
2 Underload.
3 Overload.
4 Impedance out of range.
5 Short-circuit.
22 FAULT Mains loss FAULT Mains loss FAULT Mains loss Mains supply absence Check the system connection to the