Proel AE300R1 handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 48
7
J9 – Audio output 0 dB 1 – Line Out
2 - GND
0 db Line Output to External Amplifier.
Power levels: 1.0Vrms, Ro=100ohm
Use shielded cable with min section 0.5 mm
4.d Status outputs
The unit has three relay outputs to report the state of the system
J8 – Relay outputs 1-2 – ALARM
3-4 – FAULT
5-6 – DISABLEMENT
Each relay can handle up to 500mA
ALARM e DISABLEMENT: N.O. Contact
FAULT: N.O. Contact. Please note that in the absence of power the
contact of FAULT switches to the closed position
4.e Generic messages activation contacts
The system has 8 unsupervised inputs for activating the generic and service messages recorded on uSD memory card. Each message is activated
by closing its ground input, as shown in the figure below.
The playback of the message is activated by a pulse. Releasing the contact after shorting it to ground has no effect, but the message will be
played till its end. When a message is being played, a second pulse will stop the player.
Generic messages have predefined priorities: message n has a priority over message n+1.
Example:
When message 2 is played, the closing of contact 1 will stop message 2 and start message 1
When message 2 is played, the closing of contact 2 will stop message 2
When message 2 is played, the closing of contact 3 is ignored.
This said, message 8 will has the lowest priority, but message 1 has the highest.
Each contact is active only if an associated audio file is stored in the uSD card, refer to relative menù section. OK -> 3 x DOWN -> RECORDED