User’s Manual
Trouble Reason Check Solution Remark
Lamp
not lighting
No voltage
Fuse breaking off Check fuse Change fuse
Ask a professional
to service.
Poor connection
between the plug and
socket
The connection is
loose or not
Repair or change socket
Have voltage
lamp has poor contact
or is worn down
Check the circuit and
lamp
Tighten the connection
or change a new lamp
Ask a professional
to service.
Lamp switch has poor
contact
Check the switch
Tighten the connection
or change a new switch
Condenser
fan
Not running
Compressor
works
Condenser fan broken
down
Remove condenser fan
Change condenser fan
Compressor
does not
work
Thermostat is not set
to the work position
Check the position of
the thermostat knob
Turn the thermostat
knob to the operating
position
Thermostat terminal is
not connected
properly
Check the thermostat
terminal
Reconnect the terminal
The thermostat is
worn down.
Check the thermostat
Change the thermostat
Ask a professional
to
service.
Continuous
operating
Temperature
is too high
inside of the
cabinet
Opening the door
too frequently
/
Open the door as little
as possible
Ask a professional
to service.
Too much storage
The circulation of
cooling air has been
affected
Take out part of the
storage
Leakage of refrigerant.
/
Call at a qualified
service center
Temperature
is too low
inside the
cabinet.
Thermostat does not
work properly
Check the thermostat
Change the thermostat
Ask a professional
to service.
Noise
Cooler isn’t placed levelly
Check if the four
wheels adjusted to the
same level and
touching the ground
Adjust the wheels
Ask a professional
to service
Fixing screws of compressor or
condenser are loose
Screws fixed tightly or
not
Tighten the screws
Ask a professional
to
service.
Compressor or fan defective
Check the Compressor
or fan
Ask help of professional
to repair.
Ask help of
professional to
repair.
Condenser
fan is
working, but
the
compressor
does not
operate
The plug of starter or heat relay is
loose
Check the starter and
heat relay
Install the starter or
heat relay
Ask a professional
to service.
Compressor defective
Check the resistance
of compressor CSM
terminal
Change new compressor
Ask a professional
to service.
Voltage is lower than 97V or higher
than 130V
Check the input
Voltage
Use a voltage stabilizer
Evaporator
fan
Not running
Fan switch defective
Check the resistance
of switch
Change the switch
Ask a professional
to service
Fan switch terminal is not connected
properly
Check the circuit of the
fan switch
Connect the switch
terminal or change a
new terminal