Faults
58
Symptom
Potential cause
Remedy
Triggering is not
possible.
Operating pressure is
too low.
Increase the operating
pressure of the
compressed air system
to the maximum
permissible operating
pressure.
Increase the operating
pressure at the tacker to
the maximum permissible
operating pressure.
Then trigger several
times.
If triggering works, set to
the desired operating
pressure (see page 32).
Moving parts are stuck
with lubricant after a
long period of storage.
Clean the tacker and
apply oil
(see page Fehler!
Textmarke nicht
definiert.).
Set maximum operating
pressure.
Then trigger several
times.
If triggering works, set to
the desired operating
pressure (see page 32).
Otherwise, inform
customer service
(see page Fehler!
Textmarke nicht
definiert.).