Practixx PX-AS-100 handleiding
Handleiding
Je bekijkt pagina 22 van 172

w ww.practixx.com w ww.practixx.com
22
|
GB
• Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
• If possible, keep the packaging until the expiry of the
warranty period.
• Familiarise yourself with the product by means of the
operating instructions before using for the rst time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Replace-
ment parts can be obtained from your dealer.
• When ordering please provide our article number as
well as type and year of manufacture for your equip-
ment.
8. Assembly / Before commissioning
m ATTENTION!
Always make sure the device is fully assembled
before commissioning!
8.1 Installing the lter cartridge (10) with lter bag
(11), Fig. 3 - 5
• Insert the lter cartridge (10) into the lter bag (11).
(Fig. 3 + 4)
• Press the overhang into the lter cartridge (10). (Fig.
4)
• Now t the lter cartridge (10) on the engine housing
(1). (Fig. 5)
• Place the complete engine housing (1) on the con-
tainer (3) and lock the locking hooks (9).
8.2 Installing the suction hose (5), Fig. 6 + 7
• Fit the suction hose (5) with the hose clamp (8) on
the hose port of the container (3).
• Fit the other side of the suction hose (5) with the
hose clamp (8) and hose coupling (7).
9. Start up
m ATTENTION!
Always make sure the device is fully assembled
before commissioning!
9.1 Switching on/o, Fig. 1
• To switch on, set the ON/OFF switch (4) to position “I”.
• To switch the device o again, set the ON/OFF
switch (4) to position “0”.
• Hazard due to electrical power, with the use of im-
proper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the “safety in-
structions” and the “Proper use” are observed along
with the whole of the operating instructions.
Ensure careful storage of the safety instructions.
6. Technical data
Suction port, connection Ø 100 mm
Hose length 2000 mm
Air power 215 m³/h
Pressure dierence 25000 Pa
Filter surface 0.3 m²
Container volume 65 l
Weight 5 kg
Electric motor
220 - 240 V~
50/60 Hz
Rated input 1200 W
Motor speed 35000 rpm
Technical changes reserved!
Noise and vibration
m Warning: Noise can have serious eects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
7. Unpacking
m ATTENTION!
The device and the packaging material are not
children‘s toys! Do not let children play with plas-
tic bags, lms or small parts! There is a danger of
choking or suocating!
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
Bekijk gratis de handleiding van Practixx PX-AS-100, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Practixx |
| Model | PX-AS-100 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 22264 MB |