PowerWalker Solar Inverter 5000 ZRO handleiding

84 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 20 van 84
18
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
30A (default for 5KW)
For 5KW model, default setting
is 30A and setting range is 1A,
then from 10A to 100A.
For 6KW model, default setting
is 60A and setting range is 1A,
then from 10A to 120A.
Increment of each click is 10A.
12
Setting voltage point back
to utility source when
selecting “SBU” (SBU
priority) in program 01
Default setting: 46.0V
Setting range is from 44.0V to
57.0V and increment of each
click is 1.0V.
13
Setting voltage point back
to battery mode when
selecting “SBU” (SBU
priority) in program 01
The setting range is from 48.0V to 64.0V and increment of each
click is 1.0V.
Battery fully charged
54.0V (default)
16
Solar energy priority:
To configure solar energy
priority for battery and load
SbL: Solar energy for battery
first
UCB: Allow utility to charge
battery (Default)
Solar energy charges battery
first and allow the utility to
charge battery.
SbL: Solar energy for battery
first
UdC: Disallow utility to charge
battery
Solar energy charge battery first
and disallow the utility to charge
battery.