16
02
Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current =
utility charging current +
solar charging current)
60A (default)
5KW model setting range is from
10A to 100A and increment of
each click is 10A.
6KW model setting range is from
10A to 120A and increment of
each click is 10A.
05 Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Pylontech battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
WECO battery
If selected, programs of 02, 12,
26, 27 and 29 will be
auto-configured per battery
supplier recommended. No need
for further adjustment.
Soltaro battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
LIb-protocol compatible
battery
Select “ LIb” if using Lithium
battery compatible to Lib
protocol. If selected, programs of
02, 26, 27 and 29 will be
automatically set up. No need for
further setting.