PowerWalker Solar Inverter 3600 SKY handleiding
Handleiding
Je bekijkt pagina 23 van 75

21
L3 phase The inverter is operated in L3 phase
in 3-phase application.
29
Reset PV energy
storage
Not reset(Default)
Reset
30
Start charging time for
AC charger
00:00 (Default)
The setting range of start charging
time for AC charger is from 00:00 to
23:00, increment of each click is 1
hour.
31
Stop charging time for
AC charger
00:00 (Default)
The setting range of stop charging
time for AC charger is from 00:00 to
23:00, increment of each click is 1
hour.
32
Scheduled time for AC
output on
00:00 (Default)
The setting range of scheduled Time
for AC output on is from 00:00 to
23:00, increment of each click is 1
hour.
33
Scheduled time for AC
output off
00:00(Default)
The setting range of scheduled Time
for AC output off is from 00:00 to
23:00, increment of each click is 1
hour.
34
Set country customized
regulations
India(Default)
If selected, acceptable feed-in grid
voltage range will be 195.5~253VAC.
Acceptable feed-in grid frequency
range will be 49~51Hz.
Germany If selected, acceptable feed-in grid
voltage range will be 184~264.5VAC.
Acceptable feed-in grid frequency
range will be 47.5~51.5Hz.
South America If selected, acceptable feed-in grid
voltage range will be 184~264.5VAC.
Acceptable feed-in grid frequency
range will be 57~62Hz.