PowerWalker Solar Inverter 3600 SKY handleiding

75 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 75
17
10
Charger source priority:
To configure charger
source priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Solar and Utility (default) Solar energy and utility will charge
battery at the same time.
Only Solar Solar energy will be the only charger
source no matter utility is available or
not.
11
Maximum charging
current:
To configure total
charging current for
solar and utility
chargers.
(Max. charging current
= utility charging
current + solar
charging current)
60A (default)
For 3.6KW models, setting range is
from 10A to 100A.
For 5.6KW model, setting range is
from 10A to 120A. Increment of
each click is 10A.
13
Maximum utility
charging current
2A
10A
20A 30A (default)
40A 50A
60A 70A