PowerWalker Solar Inverter 3600 LGT handleiding

85 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 85
8
P
lease follow below steps to implement PV module connection:
1. Remove insulation sleeve 10 mm for positive and negative conductors.
2. Check correct polarity of connection cable from PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable to positive
pole (+) of PV input connector. Connect negative pole (-) of connectio
n
cable to negative pole (-) of PV input connector.
Re
commended PV module Configuration
PV Module Spec.
(reference)
- 250Wp
- Vmp: 30.7Vdc
- Imp: 8.15A
- Voc: 37.4Vdc
- Isc: 8.63A
- Cells: 60
Total solar input power
Solar input
Q'ty of modules
1500W 6 pieces in series 6 pcs
2000W 8 pieces in series 8 pcs
2750W 11 pieces in series 11 pcs
3000W
6 pieces in series
2 strings in parallel
12 pcs
4000W
8 pieces in series
2 strings in parallel
16 pcs
5000W
10 pieces in series
2 strings in parallel
20 pcs
6000W
12 pieces in series
2 strings in parallel
24 pcs
Final Assembly
After connecting all wirings, please put bottom cover back by screwing two screws as shown below.

Bekijk gratis de handleiding van PowerWalker Solar Inverter 3600 LGT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPowerWalker
ModelSolar Inverter 3600 LGT
CategorieNiet gecategoriseerd
TaalNederlands
Grootte10141 MB