PowerWalker Solar Inverter 3600 LGT handleiding
Handleiding
Je bekijkt pagina 10 van 85

8
P
lease follow below steps to implement PV module connection:
1. Remove insulation sleeve 10 mm for positive and negative conductors.
2. Check correct polarity of connection cable from PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable to positive
pole (+) of PV input connector. Connect negative pole (-) of connectio
n
cable to negative pole (-) of PV input connector.
Re
commended PV module Configuration
PV Module Spec.
(reference)
- 250Wp
- Vmp: 30.7Vdc
- Imp: 8.15A
- Voc: 37.4Vdc
- Isc: 8.63A
- Cells: 60
Total solar input power
Solar input
Q'ty of modules
1500W 6 pieces in series 6 pcs
2000W 8 pieces in series 8 pcs
2750W 11 pieces in series 11 pcs
3000W
6 pieces in series
2 strings in parallel
12 pcs
4000W
8 pieces in series
2 strings in parallel
16 pcs
5000W
10 pieces in series
2 strings in parallel
20 pcs
6000W
12 pieces in series
2 strings in parallel
24 pcs
Final Assembly
After connecting all wirings, please put bottom cover back by screwing two screws as shown below.