11 OM-POWER PREP ADVANCED
Inspect the entire system for total cleanliness including the manifolds.
De-lime the wash sink by adding a de-liming agent to a full sink of warm, fresh
water and run the wash pump overnight. Ask a chemical sales representative to
recommend a specic de-liming agent known to be effective in your area.
For questions regarding the preventive maintenance procedures, please contact
the Power Soak service department at 888-994-7636.
TROUBLESHOOTING
ONLY A LIMITED NUMBER OF TROUBLESHOOTING AND REPAIR
PROCEDURES MAY BE PERFORMED BY THE FACILITY OWNER OR
MANAGER. ANY TROUBLESHOOTING OR REPAIR THAT REQUIRES THE
REMOVAL OF FASTENERS OR THAT ENTAILS ELECTRICAL SERVICE MUST
NOT BE ATTEMPTED BY ANYONE OTHER THAN AN AUTHORIZED SERVICE
AGENCY. TO OBTAIN THE NAME OF A RECOMMENDED SERVICE AGENT IN
YOUR AREA, PLEASE CALL THE POWER SOAK SERVICE DEPARTMENT AT
AT 888-994-7636.
SYMPTOM POSSIBLE CAUSE REMEDY
Pump motor will
not run
Circuit breaker
accidentally turned off
Turn breaker on.
Circuit breaker tripped Investigate reason for tripping, e.g.
damaged wiring, undersized breaker.
Contact Power Soak service or an
authorized service agency.
Motor thermal overload
tripped
Investigate reason for overload tripping,
e.g. debris stuck in pump impeller. If
debris removal requires that you remove
any fasteners, contact Power Soak
service or an authorized service agency.
Once rectied, reset thermal overload
by pressing button on bottom of motor
junction box.
Start capacitor
defective (single
phase motors only)
Replace capacitor. To do this, contact
Power Soak service or an authorized
service agency.
Unit too warm Pump clogged with
food
Ensure door / drawer is fully closed.
Motor is running on
the wrong voltage
(initial installation)
Lock and tag out the electrical power from
the unit. Remove the three adapter plate
retaining nuts adjacent to the motor. Slide
the motor, adapter plate, and impeller out
of the pump housing. Remove debris from
the impeller and reassemble. Contact
Power Soak service or an authorized
service agency for this service.
Motor is running the
wrong direction (initial
installation)
For three phase motors, reverse any two
motor leads. For single phase motors,
reconnect motor internal leads according
to the motor nameplate instructions.
Contact Power Soak service or an
authorized service agency to safely change
the rotation.
Unit makes a
loud, steady
noise when
running
Debris caught in the
motor’s cooling fan
Lock and tag out the electrical power
from the unit, remove the motor fan cover,
and remove the debris. Replace the fan
cover and restore the power. For this
task, Contact Power Soak service or an
authorized service agency.
Motor seal running dry Lock and tag out the electrical power
from the unit, remove the motor fan cover,
and squirt some low viscosity oil such as
WD40 between the fan and the motor end
bell. Replace the fan cover and restore the
power. Contact Power Soak service or an
authorized service agency for service of
this nature.
Debris caught in the
pump impeller
Lock and tag out the electrical power
from the unit. Remove the three adapter
plate retaining screws adjacent to the
motor. Slide the motor, adapter plate, and
impeller out of the pump housing. Remove
debris from the impeller and reassemble.
Contact Power Soak service or an
authorized service agency for this service.