6 OM-POWER PREP ADVANCED
IMPORTANT
: THE MOTOR MUST ROTATE IN THE CORRECT DIRECTION FOR THE MACHINE
TO OPERATE PROPERLY.
Shelving
Reinstall any shelving that was removed for convenience of installation. If the shelving
is damaged or corroded, it is recommended that the shelving be replaced. Remember
that whatever equipment or supplies are located above the sink might accidentally fall
into the food being processed by the Power Prep Advanced.
VALIDATING THE INSTALLATION
IMPORTANT
: MOTOR ROTATION MUST BE CORRECT FOR THE MACHINE TO OPERATE
CORRECTLY.
TESTING THE COMPONENTS
Check for Leaks
• Turn on the water supply and inspect all joints for leaks.
• Close the drain valve(s), ll the sink(s) with water, and inspect the drain ttings for
leaks.
• Open the drain valve(s) and inspect the drain joins for leaks as the water is
draining from the sink.
Check the Electrical Installation
• Verify that there are no loose wires or open holes in the electrical enclosure.
• Fill the wash sink with water and turn the control handle to ON. Have a qualied
electrician verify that the amp draw on the electrical supply is within the
specications on the identication tag.
• Check motor rotation for the correct direction as indicated by the arrow on the
pump housing.
Check the Faucet Operation
• Open each faucet knob and verify that water ows from each hand control. Verify
that hot and cold water are running from the correct hand control.
• With the water valves open, turn the center knob to see that it will shut off ow to
the faucet and that the hand sprayer is still functional.
• Purge the water lines according to local code requirements.
IMPORTANT
: INSTALLER IS RESPONSIBLE FOR ALL PLUMBING TO CONFORM TO LOCAL
BUILDING CODES WHICH MAY BE DIFFERENT FROM ILLUSTRATIONS
SHOWN IN THIS MANUAL.
Plumbing Connections
Connect the water supply lines to the faucets. Connect all the drains to the waste
drain connection.
DO NOT USE HOSES to make the pressure connections to the faucets. Maximum
water inlet pressure is not to exceed 125 psi (8.6 Bar), minimum water pressure to be
not less than 50 psi (1.2 Bar).
Electrical Connections
An equipotential bonding terminal is provided on the side
of the wash sink near the serial tag and identied with
the symbol shown at right. This terminal is used to make
a connection for properly grounding the machine. This
connection must be completed by a qualied electrical
technician.
The nal electrical connections between the Power Prep
Advanced and the electrical supply must be made by a
licensed electrician. The Power Prep Advanced has several
options for motors. Review the information tag on the side
of the wash tank or the pump motor for determining the specic requirements of
the electrical system (See Verify the Electric Requirements section of this instruction
booklet).
CAUTION
: DO NOT RUN THE POWER PREP ADVANCED EMPTY FOR MORE THAN A
FEW SECONDS. DRY OPERATION OF THE PUMP WILL OVERHEAT THE PUMP
SEAL.
Checking the Motor Rotation
The motor must rotate in the correct direction in order for the Power Prep Advanced
to function properly. An arrow indicating the direction of rotation is located on the
pump housing. Running the motor in the wrong direction does not damage the motor
or pump, but the pump will not circulate water in the wash sink correctly. After the
connection to the electrical supply is properly made, turn the motor on momentarily
and watch the cooling fan blades on the end of the motor to see that the motor is
turning in the correct direction. The fan blades can be seen through the vent holes
on the end of the motor. It is usually necessary to watch the fan as the motor coasts
to a stop, because the fan is difcult to see when the motor is running at full speed.