Posiflex RA-105 handleiding

128 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 93 van 128
Enter Setup
Exit Setup
- 102 -
6.22.3 Length Settings
The user can set the maximum and minimum length of barcode reading. If read
barcode length does not match the set effective length, the barcode reading is
unsuccessful, and the scanner will not send the barcode content to the host.
The barcode length is composed of "minimum length" and "maximum length". If the
maximum length is less than the minimum length, only barcodes of these two
lengths can be read. If the maximum length is equal to the minimum length, only this
length is supported.
CodaBlock A Maximum decoding
length
$>: R000F62.<$
CodaBlock A Minimum decoding
length
$>: R000F82.<$
Example: Restrict the scanner to only read barcodes with a minimum of 4 bytes
and a maximum of 100 bytes
1) Scan code "Enter setup"
2) Scan code “CodaBlock A Minimum decoding length”
3) Scan Data code “4” (in Appendix)
4) Scan code "Save" (in Appendix)
5) Scan code “CodaBlock A Maximum decoding length”
6) Scan Data code “6” “4” (in Appendix)
7) Scan code "Save" (in Appendix)
8) Scan code "Exit setup"