Enter Setup
Exit Setup
- 32 -
Example: Set the reading interval time 500ms (Data code expressed in
hexadecimal)
1) Scan code “Enter setup”
2) Scan code “Decode Session Timeout”
3) Scan Data code “1” (in Appendix)
4) Scan Data code “F” (in Appendix)
5) Scan Data code “4” (in Appendix)
6) Scan code “Save” (in Appendix)
7) Scan code “Exit setup”
4.2.5 Single Scanning Time
Enabling the scanning till the it turned off automatically when the timeout is
reached.
Single reading timeout
$>:R000064.<$
Example: Set the single reading time 4000ms (The data code is expressed in
hexadecimal)
1) Scan code “Enter setup”
2) Scan code “Single reading timeout”
3) Scan Data code “F” (in Appendix)
4) Scan Data code “A” (in Appendix)
5) Scan Data code “0” (in Appendix)
6) Scan code “Save” (in Appendix)
7) Scan code “Exit setup”