Posiflex MT-6210W handleiding
Handleiding
Je bekijkt pagina 35 van 128

Enter Setup
Exit Setup
- 44 -
CHAPTER 5: DATA EDITING
In daily applications, we need to edit the data before outputting it to facilitate data
differentiation and processing.
Data editing includes: adding prefix, adding suffix, decoding information, adding
terminator.
The default output sequence of processed data is as follow:
<prefix> <barcode data><suffix><terminator>
5.1 Prefix/Suffix Setting
Enable all prefixes and suffixes
$>:S80804E.<$
Disable all prefixes and suffixes
$>:S80004E.<$
5.2 Prefix Sequence Setting
Customized prefix + Code ID +
AIM ID
$>:S01014E.<$
Code ID + Custom prefix + AIM ID
(Default)
$>:S01004E.<$