3PCLIOB4K0PO
ER22 Internal error inside TC Cooktop switches
off after3.5-7.5
sec.
- Contact technical
support.
ER31 Congurations inside Tou-
ch Control and induction
are incongruent
ER31 is displayed
continuosly
The conguration data
inside the induction
generator is different
from the conguration
inside the TC
Download congu-
ration. If error is still
occurring, replace TC.
If error is still occur-
ring, contact technical
support..
ER36 Internal error inside TC Cooktop switches
off
- Replace TC
ER42 Secondary power supply
implausible
12V or 5V too high / too low
ER47 No communication to at
least one LIN subscriber
ER47 is displayed
continuously
LIN cable damaged
No power voltage sup-
ply for LIN subscriber
LIN subscriber de-
fective
Contact technical
support.