2.5 Wiring the Faulty Alarm Contact
The faulty alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the Industrial Ethernet Extender will detect
the fault status of the power failure and then forms an open circuit. The following
illustration shows an application example for wiring the faulty alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Alarm
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range of 12 ~
24AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A currents.
2.6 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
DC Input:
12-54V , 7A max.
V1+
PWR1 Alarm
V2+
PWR2
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
Earth Ground
EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.