3.4 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial Gigabit Ethernet Switch
is used for two DC redundant power inputs. Please follow the steps below to insert
the power wire by professionals.
When performing any of the procedures like inserting the wires or tight-
ening the wire-clamp screws, make sure the power is OFF to prevent
from getting an electric shock.
Lorsque vous effectuez l’une des procédures telles que l’insertion des
fils ou le serrage des vis de serrage, assurez-vous que l’alimentation est
coupée pour éviter tout choc électrique.
IGS-500T
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1,
or contacts 5 and 6 for POWER 2.
Max. Fault Alarm Loading: 24V, 1A
V1+
V2+
PWR1
PWR2Alarm
DC Input: 9-48V
, 0.28A max.
AC Input: 24V
, 0.3A max.
1 2 3 4 5 6
Wire Range Wire Type FW
Torque In-lbs (N.m)
12-24 AWG Str/Sol
Cu 2 5 (0.56)
2. This product is supplied with a UL-listed power adapter or power source of
24V AC, 50/60Hz 0.3A (max.) or 9-48V DC, 0.28A (max.) and the maximum
temperature of 75°C.