1. The power input range is 9V ~ 48V DC for Industrial Gigabit
Ethernet Switch with support for 24V AC.
2. Use one power input when using 24V AC.
1. La plage d’entrée d’alimentation est de 9V ~ 48V DC et prend en
charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez 24V AC..
3.5 Wiring the Fault Alarm Contact (IGS-500T only)
The fault alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the Industrial Gigabit Ethernet Switch
will detect the fault status of the power failure and then forms an open circuit.
The following illustration shows an application example for wiring the fault alarm
contacts.
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Alarm
Insert the wires into the fault alarm contacts
Wire Range Wire Type FW
Torque In-lbs (N.m)
12-24 AWG Str/Sol
Cu 2 5 (0.56)
Alarm relay circuit accepts up to 24V DC, 1A