User’s Manual of IGS-5225 series
314
Defects : A MEP can detect and report a number of defects, and multiple
defects can be present at the same time. This is indicated the following letter
code.
Code
Defect
Description
-
Defect not present
Defect not present
R
someRDIdefect
RDI received from at least one remote MEP
M
someMACstatusDefect
Received Port Status TLV != psUp or Interface
Status TLV != isUp
C
someRMEPCCMdefect
Valid CCM is not received within 3.5 times CCM
interval from at least one remote MEP
E
errorCCMdefect
Received CCM from an unknown remote MEP-
ID or CCM interval mismatch
X
xconCCMdefect
Received CCM with an MD/MEG level smaller
than configured or wrong MAID/MEGID (cross-
connect)
CCM Rx
Valid: Total number of CCMs that hit this MEP and passed the validation test.
Invalid: Total number of CCMs that hit this MEP and didn't pass the validation
test.
Errors: Total number of out-of-sequence errors seen from RMEPs.
CCM Tx
Total number of CCM PDUs transmitted by this MEP.