2.3 Switch Upper Panel
The upper panel of the Industrial Ring Ethernet Switch consists of one terminal block
connector within two DC power inputs. Figures 3 and 4 show the upper panels of
the Industrial Ring Ethernet Switches.
DC Input: 9-48V
, 1A max.
AC Input: 24V
, 0.8A max.
Switch
Ring
Fiber
Mode
V1+
V2+
PWR1
PWR2Alarm
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
Figure 3: IFGS-620TF Upper Panel
DC Input:
12-54V , 7A max.
V1+ V2+
PWR1 Alarm PWR2
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
Figure 4: IFGS-624PTF Upper Panel
2.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Ring Ethernet
Switch is used for two redundant power inputs. Please follow the steps below to
insert the power wire.
When performing any of the procedures like inserting the wires or tight-
ening the wire-clamp screws, make sure the power is OFF to prevent
from getting an electric shock.