Planet GS-6322-48UP4X handleiding
Handleiding
Je bekijkt pagina 142 van 566

User’s Manual of GS-6322 Managed Switch Series
142
4.2.7 Power Management
The GS-6322-Series is designed with two extractive modular power supply slots to support Redundant Power Supply(RPS)
mode or Extended Power Supply(EPS) mode via software setting to handle the demands of power redundancy or additional
power to PoE++ ports as needed.
◼ RPS (1+1) mode: Where critical services are supported by PoE application, the secondary PSU is needed to provide
backup power in the event of a power outage. When two PSUs are installed, the power budget is the same as that of one
PSU.
◼ EPS (2+0) mode: Where more PoE budget is required to support complete application, the secondary PSU can provide
additional PoE power. The two PSUs combined are able to provide a maximum of total PoE power.
Users can choose one or dual power supplies with the initial installation.
PSU Module
Operation mode
PoE Budget with
One 1200W PSU
PoE Budget with
Two 1200W PSUs
Power
Redundancy
RPS mode (1+1)
1000W
1000W
Yes
EPS mode (2+0)
1000W
2200W
--
Example on power supply: PWR-CRPS1200
The factory default power configuration are shown as follows.
Default Power Module Operation Mode: EPS