2.7 Before initial use
Adjustment of the small-burning-position:
Ignite the burner and leave it in Min position.
When the flame is at least 4 mm high, the gas is well-distributed.
The flame must not go out when the setting is adjusted from MAX to MIN.
After setting of the 4 burners, a pressure testing must be carried out.
2.8 Conversion from NG to LPG/LPG to NG
DANGER! THE CONVERSION MUST BE CARRIED OUT BY AN
AUTHORIZED PROFESSIONAL ONLY!
3. Main components