10.1b.2. If selected a Custom_3rd lter
Output[x] [Name] LPF
->Custom_3rd F = 250Hz
→ Filtx F= 250Hz Q = 0.3 [2
nd
Ord Cell x ] x=1 [Freq.] 20Hz [Q] 0.05
: : :
[Q not available] x=2 20kHz 10.00
10.1b.3. If selected a Custom_4th lter
Output[x] [Name] LPF
->Custom_4th F = 250Hz
→ Filtx F= 250Hz Q = 0.3 [2
nd
Ord Cell x ] x=1 [Freq.] 20Hz [Q] 0.05
: : :
x=2 20kHz 10.00
Once editing the Cells “Filtx”, pressing the Enter Button can be accessed also for the Custom Filters the page for the fast
frequency setting, as available for the NOT Custom Filters and which way of working is described at the point 10.1a.
11. Out-[x] EQ-[x] (X from 1 to 4)
Byp = Off Type = Y (Y = Peaking_Eq, Hi-Shelv_Q, Lo-Shelv_Q, Lo-Pass_Q, Hi-Pass_Q, All Pass_2)
-> Byp = Off Type = Y PM1 N/A Off Peaking_Eq
: :
On Notch Filt
Through the PM2, it is possible to Byp the single selected lter.
Through the PM3, it is possible to select one of the 17 available
lters' type.
Once selected the lter Type and NOT in Byp mode, pressing
again the ENTER button can be accessed the selected lter's editing page.
11.1 Out-[x] EQ-[x] (X from 1 to 4)
-> Byp = Off Type = Y
11.1a. If you selected a Peaking_Eq lter, then the lter can be set by
the following parameters
Out-[x] EQ-[x] (up to 5 lters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00 [Freq.] 20Hz [Amp.] -12.0 dB [Q] 0.30
: : :
20kHz +12.0 dB 20.00
11.1b. If you selected a Hi-Shelv_Q (variable Q High Shelving) lter,
then the lter can be set by the following parameters
Out-[x] EQ-[x] (up to 5 lters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00 [Freq.] 20Hz [Amp.] -12.0 dB [Q] 0.30
: : :
20kHz +12.0 dB 20.00
11.1c. If you selected a Lo-Shelv_Q (variable Q Low Shelving) lter,
then the lter can be set by the following parameters
Out-[x] EQ-[x] (up to 5 lters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00 [Freq.] 20Hz [Amp.] -12.0 dB [Q] 0.30
: : :
20kHz +12.0 dB 20.00
11.1d. If you selected a Lo-Pass_Q (variable Q Low Pass) lter,
then the lter can be set by the following parameters
Out-[x] EQ-[x] (up to 5 lters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00 [Freq.] 20Hz [Amp.] ----- [Q] 0.30
: : :