14
DMP8800
English
RM-2VR REMOTE LEVEL CONTROL
With a single RM-2VR you will be able to control up to 2
channels of the DMP8800 Digital Matrix Processor at a
single time� Up to four RM-2VRs can be utilized at any
one time to control all 8 outputs�
WIRING
The RM-2VR can be wired to the “Remote Level Control”
section on the rear of the Asystems DMP8800 digital
matrix processors�
As shown, there are pins for each of the devices’ 8 input
mixes in addition to a +5V power pin and a grounding
pin� Each of the 8 pins corresponds with the output mix
of the device you’re using� This being the case, for a
single RM-2VR to control channels 1 and 2, it should be
wired thusly:
Channel 2 Ground is internally
wired to channel 1 ground
SETUP AND OPERATION
To utilize the RM-2VR you will need
to activate the remote within the DMP
software� At the bottom of each channel
within the “Control Panel” window you
will be able to find an on/off button for the
Remote level control� You will also be
able to view the remote level in the virtual
rotary control found directly below this
button�
DMP8800
Do not connect the RM-2VR grounding
pins to any other external grounds�