6.8.2 Design of a separate power supply for the SCK-M-U-1500V
voltage measuring module
You can use the voltage measuring module as a simple analog measuring transducer out-
side of the SOLARCHECK device family. In this case, power is not supplied via the connec-
tion to the SCK-M-I-8S-20A SOLARCHECK current measuring module, but must be sup-
plied separately. A 24 V DC power supply must be provided. The typical current
consumption is 8 mA. The maximum current consumption is 65 mA. The maximum current
consumption only occurs, if the input voltage falls significantly below the specified minimum
input voltage U
N
.
Figure 6-17 Performance characteristics of the SCK-M-U-1500V voltage measuring
module
0
50
100
150
200
250
0 5 10 15 20 25 30 35
P [mW]
I [mA]
U [V]
U = 21,6…30 V
N
P [mW]
I [mA]
0
10
20
30
40
50
60
70
300