5.4 Power supply
In addition to collecting data, the communication module also supplies power to the con-
nected measuring modules. The power supply for the communication module and the con-
nected measuring modules therefore has to be incorporated in the design.
– Input voltage: 24 V DC (-10% ... +25%)
– For current consumption, all connected measuring modules must also be taken into
consideration.
Let us assume 20 mA for the communication module and the sum of the typical current con-
sumption of all connected measuring modules. To account for current peaks, multiply the
result by 3. For input voltages other than 24 V DC, refer to the current consumption charts
for the modules in Section “Design of the power supply” on page 60.