SOLARCHECK string current measurement with SCK-M-I-…
105608_en_02 PHOENIX CONTACT 17
3 SOLARCHECK string current measurement with
SCK-M-I-…
Various device versions are available for string current measurement. The device designa-
tion indicates the number of current measuring channels and their measuring range final
value. Hall sensors are used for contact-free current measurement. The devices also have
a digital input, internal temperature indication, and some have an analog interface for con-
necting a SOLARCHECK voltage measuring device.
3.1 Safety notes on the device
Opening or modifying the device is not permitted. Do not repair the device yourself; re-
place it with an equivalent device. Repairs may only be carried out by the manufacturer.
The manufacturer is not liable for damage resulting from non-compliance.
The termination area must be covered after installation to ensure sufficient protection
against accidental contact with live parts (e.g., installation in a distributor box or control
cabinet).
3.2 Function
Table 3-1 Function matrix for current measuring modules
SCK-M-
I-8S-20A
x - x x x x x
SCK-M-
I-4S-20A
- x x - x x x
Module
8-channel current
measurement up to
4-channel current
measurement up to
Reverse current detec-
Analog input for voltage
measuring devices
Digital input
Internal temperature
measurement
Power supply via SCK-
C-MODBUS
Block diagram
SCK-
BUS
OUT
U-IN
Digital
IN
1
+
2
3
4
5
6
7
8
I-IN
μ
C
COM
8x
0...10V
1
2
3
4
I-IN
m
C
SCK-
BUS
OUT
COM
4x
Digital
IN