Electrical potential and data routing (Inline)
6452_en_11 Phoenix Contact 85 / 188
8.1.7 Example of a circuit diagram
Figure 8-1 Potential routing within an Inline station
The illustrated Inline station is a typical example. It shows the supply and provision of dif-
ferent voltages and their forwarding via potential jumpers. Explanations for this can be
found in the following sections.
BK (PWR IN)
IB IL 24 SEG/F
IB IL 24 PWR/IN
IB IL 400
ELR 1-3A
IB IL 24 SEG
+
-
U
S
U
M
Local bus
U
L+
U
ANA
U
L-
IB IL 400
ELR 1-3A
M1
S1.1 S1.2
M2
S2.1 S2.2
U
S
U
M
U
S
U
M
U
M2
+
-
U
M1
24 V
7,5 V
+
-
U
BK
Protocol
chip
Mx Main circuit (e.g., M1, M2)
Sx,y Segment circuit y in main circuit x (e.g., S2.1, S2.2)
BK (PWR IN) Bus coupler in conjunction with a power terminal, if required
U
BK
Bus coupler supply (supply for bus coupler, generates U
ANA
and U
L
)
U
M
Main supply (I/O supply in the main circuit)
U
S
Segment supply (I/O supply in the segment circuit)
U
ANA
I/O supply for analog terminals
U
L
Communications power
Local bus Data jumper for the local bus
Ground (GND for the supply voltages U
M
and U
S
)