CONTACTRON Speed Starter
66 / 150 Phoenix Contact
109908_en_02
9.2.4 Rotary switch in “SPEED1”/“SPEED2” position when STOP
The display shows the stored frequency and the LED “Hz” is on. Depending on the stored
direction, the LED “R” or “L” is on.
The default standard value is 50.0 Hz.
The maximum value depends on the parameter “3. oF - highest output frequency” and
the minimum value is 0.0 Hz.
For a lower speed, press <DOWN>. For a higher speed, press <UP>.
The value in the display changes (steps of 0.1) and starts to flash.
Press <SET/RESET> to store the value.
The displayed value stops flashing and is stored.
LED “R” (depending on the stored direction) starts to flash.
Press <DOWN> or <UP> to change the running direction.
“R” changes to “L” (backwards if the buttons are pressed again) and keeps flashing.
Press <SET/RESET> to store the setting for the running direction.