Phoenix Contact CSS 1.5-1/3 handleiding
Handleiding
Je bekijkt pagina 32 van 152

CONTACTRON Speed Starter
32 / 150 Phoenix Contact
109908_en_02
5.2.2 PE terminal
Figure 5-3 PE terminal
NOTE:
The specified minimum PE conductor cross-sections (IEC/EN 61800-5-1) must be
maintained.
A reinforced grounding (PE) must be connected, as required by standard
IEC/EN 61800-5-1. The cable cross-section must be at least 10 mm² or the ground
system must consist of two separately connected grounding cables.
The PE conductor’s cross-sectional area must be the same as the phase conductor’s
cross-sectional area. The terminals marked with must be connected to the
earth-current circuit.
05 -0 Nm. 9 .78
5 - lb In,2 6,9
AWG 14 8-
2, -105mm
2
M4
Bekijk gratis de handleiding van Phoenix Contact CSS 1.5-1/3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Phoenix Contact |
| Model | CSS 1.5-1/3 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 11973 MB |







