Description of parameter settings
109908_en_02 Phoenix Contact 87 / 150
10.5.10 Analog input
As of version 1.03, this setting is only visible in the options menu of the
CONTACTRON Speed Starter when the analog input is activated, see
“PTC/AI, thermal contact, and thermistor relay” on page 85.
The CONTACTRON Speed Starter has an input for analog signals (0 V ... 10 V,
4 mA ... 20 mA) so that the speed can be controlled variably within the parameterized
range. When the analog input is enabled, it has priority over all other speed settings.
10.5.11 Lowest output frequency
As of version 1.03, this setting is only visible in the options menu of the
CONTACTRON Speed Starter when the analog input is activated, see “PTC/AI,
thermal contact, and thermistor relay” on page 85.
Can be set
during operation
Clear text display Parameter name Setting range Default
setting
10. cv - AI input mode Analog input circuit volt: voltage range 0 V ... 10 V
curr: current range 4 mA ... 20 mA
Volt
Can be set
during
operation
Clear text display Parameter name Setting range Default
setting
- 11. LF - lowest output
frequency
Lowest output frequency 0.0 Hz ... set maximum frequency 0.0 Hz