10.2 Rotary switch in “RAMP” position
In this position, you can set the acceleration and deceleration time. The maximum value
is up to 100 s. The adjustment time means the required time for the parameter to accel-
erate from 0 Hz to the reference point 50 Hz. The actual acceleration time is proportional
to the change in speed (Δn).
Δt = acceleration time for Δf
Δf = frequency change
Figure 10-2 Acceleration and deceleration time
Can be set during operation Clear text display Parameter name Setting range Default setting
- Ramp time 0.1 s ... 100.0 s 1.0
Δt =
T
Ramp
x Δf
50 Hz
f[Hz]
t[sec]
T
Ramp
50
25
f
t