Phoenix Contact CSS 1.5-1/3-EMC handleiding

152 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 107 van 152
STO – Safe Torque Off
109908_en_02 Phoenix Contact 107 / 150
13.4 Safety parameters
Table 13-1 System conditions
Specification Parameter
Database for failure rates SN 29500
Stop category [IEC/EN 60204-1] 0
Ambient temperature [°C] 60
Table 13-2 Safety parameters for EN ISO 13849-1
Specification Parameter
Performance level e
Category 4
MTTF
d
[years] 399
DC
avg
[%] - diagnostic coverage High (>99)
Table 13-3 Safety parameters for IEC 61508, Part 1-7 and IEC/EN 62061 - high
demand
Specification Parameter
System type (consisting of subsystems) Type A
SIL 3
SILCL 3
HFT - hardware failure tolerance 1
SFF [%] - safe failure fraction 99.9
DC [%] - diagnostic coverage 99.9
PFH [1/h] - probability of a dangerous failure per hour 10.9 * 10
-12
Mission time [years] 20