Phoenix Contact CSS 0.55-1/3 handleiding

152 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 12 van 152
CONTACTRON Speed Starter
12 / 150 Phoenix Contact
109908_en_02
Output terminals of the main circuit
Use well-insulated motors to prevent any electric leakage current from motors.
When the CONTACTRON Speed Starter output terminals U, V, and W are connected
to the motor terminals U, V, and W respectively, the “R” LED indicator on the digital
control panel is on. This means the CONTACTRON Speed Starter executes forward
running, and the motor rotates clockwise (viewed from the shaft end of the motor).
On the contrary, when the “L” LED indicator is on, the CONTACTRON Speed Starter
executes reverse running, and the motor rotates counterclockwise as shown in
Figure 1-1. If the CONTACTRON Speed Starter executes forward running but the
motor rotates counterclockwise, exchange any two of the motor leads (U, V, W).
Figure 1-1 Reverse running
Reverse running