Phoenix Contact CHARX SEC-3050 handleiding
Handleiding
Je bekijkt pagina 24 van 178

CHARX control modular
24 / 176 Phoenix Contact
109999_en_06
4 Meter 1 12 V Power supply, +12 V
2 GND Power supply, ground
3 A+ RS-485, connection for energy measuring device
4 B-
5 RxD Reserved for future applications
6 TxD
5 RCM 1 12 V Power supply for residual current sensor
2 GND
3 ER1 Trigger signal for residual current detection,
Active High (0 V = no error)
Internal
pull-up to
12 V
4 ER2 Trigger signal for residual current detection,
12 V Active Low (12 V = no error)
5 TST Test and reset signal of residual current sensor (+12 V)
6 NC Signal is not connected
6 Socket 1 CP Control pilot in accordance with IEC 61851-1, Annex A
2 PP Proximity (proximity detection in accordance with
IEC 61851-1, Annex B)
3 LO- Control of connector locking mechanism, ±12 V
4 LO+
5 LD1 Feedback signal for locking
6 LD2
7 Contactor C1 Mains input voltage for controlling the charging contactor
(floating switch contact)
CHARX SEC-
1000
only
C2
NC (2x) Not connected
8 Contactor C1 / L Mains input voltage for controlling the charging contactor
(floating switch contact) and zero cross detection during
communication in accordance with ISO/IEC 15118, to be
connected to the supply network phase
CHARX SEC-
3xxx
only
C2 / L* Switching output for controlling the charging contactor
N (2x) Neutral conductor for zero cross detection during commu-
nication in accordance with ISO/IEC 15118
Table 2-2 Connections and operating elements on the charging controller
No. Connection
group
Pos. Designa-
tion
Description Note