CHARX control modular
22 / 176 Phoenix Contact
109999_en_06
Once the server has been restarted and it has detected the client, it waits three minutes
before configuring the client. The client is then restarted. Once the boot phase has been
completed successfully, all the charging controllers gradually appear in the dashboard.
This process takes around five to ten minutes to complete.
To speed up network setup, you can configure the charging controllers for client mode
manually via the WBM prior to switch-over (see “System Control/Module Switch” on
page 133).
You can operate a client outside of the client/server group again and restore the disabled
services. To do this, connect to the charging controller via the USB interface and undo the
relevant configuration settings in the web-based management (see “System Con-
trol/Module Switch” on page 133).
NOTE:
As of software version 1.7, clients are coupled with the connected server. This cou-
pling process takes place automatically. If no coupling has been performed yet,
there is no need to do anything. If the server module is replaced or a previously cou-
pled client is operated on another server, you must decouple them manually. To do
this, connect to the clients via USB and decouple them in the web-based manage-
ment under “System Control, Module Switch”.