1.4 Safety notes
Observe the country-specific installation, safety, and accident prevention regulations.
Installation by specialist personnel only
The charging controller is a built-in device. Installation, startup, operation, and mainte-
nance may only be carried out by qualified electricians. Follow the installation instruc-
tions as described. When installing and operating the charging station for electric vehi-
cles, the applicable regulations and safety directives (including national safety
directives), as well as general technical regulations, must be observed. The safety data is
provided in this manual, in the packing slip, and on the certificates (conformity assess-
ment, additional approvals where applicable) in the download area for the relevant item.
For example, for the item CHARX SEC-3100, 1139012, at phoenixcon-
tact.com/qr/1139012.
Danger to life from electric shock
It may be necessary to connect to hazardous contact mains voltage to operate the
charging controller. Protection against electric shock must be ensured.
Dangerous contact voltage
You may only install and remove the device when the power supply is disconnected. Only
operate the device in a closed housing that protects against electrical shock.
Provide a disconnecting device for disconnecting the charging station from the voltage.
Potentially lethal voltage
The device contains dangerous live elements and high levels of stored energy. Never
carry out work when voltage is present.
Before startup, observe the following
– Mains connection must be performed by specialist personnel. Protection against
electric shock must be ensured.
– It must be possible to disconnect the device other than via the power supply in ac-
cordance with the regulations of IEC 61010 (e.g., via line protection on the primary
side).
– Ensure supply lines have sufficient fuse protection and are the correct size.
– Ensure output cables are the correct size for the maximum device output current or
have separate fuse protection.
– Ensure sufficient convection.
Risk of burns
The temperature of the connection terminal blocks may be increased during operation.
Electrostatic discharge
The device contains components that can be damaged or destroyed by electrostatic dis-
charge. When handling the device, observe the necessary safety precautions against
electrostatic discharge (ESD) in accordance with EN/IEC 61340-5-1.
Bekijk gratis de handleiding van Phoenix Contact CHARX SEC-3050, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Phoenix Contact |
Model | CHARX SEC-3050 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 18845 MB |