Startup
109484_en_01 PHOENIX CONTACT 65 / 94
6.4 Switching on
Switching on and booting of the DC power module is enabled via three procedures:
1. Front plate pushbutton
Pressing the front plate pushbutton on the DC power module (button pressed).
2. Remote OFF signals
The Remote OFF function uses an N/C contact. To enable the charging point, the con-
tact between the following terminal points has to be closed.
– Charging point 1 (DC power modules 1 and 2): terminal block X12.1/2
– Charging point 2 (DC power modules 3 and 4): terminal block X12.4/5
3. System configuration via the CAN bus
Configuration includes:
– Configuration of the charging parameters (charging voltage and current)
– Configuration of maximum values (for safety considerations)
– Enable configuration for starting the charging process
– Further coordinated parameters
The required data is transmitted to the system via a proprietary CAN bus. Phoenix Contact
can provide you with a detailed description of the CAN protocol.