Startup
109484_en_01 PHOENIX CONTACT 65 / 94
6.4 Switching on
Switching on and booting of the DC power module is enabled via three procedures:
1. Front plate pushbutton
Pressing the front plate pushbutton on the DC power module (button pressed).
2. Remote OFF signals
The Remote OFF function uses an N/C contact. To enable the charging point, the con-
tact between the following terminal points has to be closed.
Charging point 1 (DC power modules 1 and 2): terminal block X12.1/2
Charging point 2 (DC power modules 3 and 4): terminal block X12.4/5
3. System configuration via the CAN bus
Configuration includes:
Configuration of the charging parameters (charging voltage and current)
Configuration of maximum values (for safety considerations)
Enable configuration for starting the charging process
Further coordinated parameters
The required data is transmitted to the system via a proprietary CAN bus. Phoenix Contact
can provide you with a detailed description of the CAN protocol.