Phoenix Contact AXL F BP SE4 handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 29 van 40
Error codes
8663_en_08 Phoenix Contact 29 / 38
0F01 Hardware fault or firmware error Restart the device. If the problem per-
sists, please contact Phoenix Contact.
0F02
0F03
0F04 Inconsistent parameters. Check the parameters.
0F05 PDI object
index
Invalid parameters. Check the parameters.
0F06 PDI object
index
Access not supported. Check the invocation.
0F08 PDI object
index
Maximum number of permitted parallel PDI services
exceeded.
Wait until the services have been pro-
cessed.
0F0C Unknown
Variable_ID
Incorrect variable ID for Set_Value or Read_Value. Check the invocation.
0F0D Internal error Restart the device. If the problem per-
sists, please contact Phoenix Contact.
0F11 Internal error
0F12 Device cannot be reached (timeout). Check the device.
0F13 Device cannot be reached because it was removed. Check the bus configuration.
0F21 Invalid
device
number
Invalid slot number.
(Value is 0 or greater than the maximum number of de-
vices)
Check the invocation.
0F22 Invalid
device
number
Slot is not active. Check the invocation.
0F23 Invalid data
length
Invalid data length. Check the invocation.
0F24 Invalid
number of
parameters
Invalid number of parameters. Check the invocation.
0F31 Internal error Restart the device. If the problem per-
sists, please contact Phoenix Contact.
0F32
0F33
Table 3-3 Error codes when invoking the PDI services [...]
Code
(hex)
Additional
code
Meaning Remedy