17EN
7 Troubleshooting
This chapter summarizes the most common problems you could encounter with the appliance. If you
are unable to solve the problem with the information below, contact the Consumer Care Center in your
country.
Problem Possible solution
The appliance does not
work properly.
The lter replacement alert has been on continuously but you have not
replaced the corresponding lter. As a result, the appliance is now locked.
In this case, replace the lter and long press and to reset the lter
lifetime counter.
The airow that comes
out of the air outlet is
signicantly weaker
than before.
The surface of the lter is dirty. Clean the surface of the lter (see the
chapter “Cleaning and maintenance”).
The air quality does not
improve, even though
the appliance has been
operating for a long
time�
Check if the packing material is removed from the lter.
The lter has not been placed in the appliance. Make sure that the lter
(FY2200) is properly installed.
The particle sensor is wet. The humidity level in your room is high and
causes condensation. Make sure that the particle sensor is clean and dry
(see the chapter “Cleaning and maintenance”).
Room size is large or the outdoor air quality is poor.
For optimum purication performance, please close the doors and
windows when operating the air purier.
There are indoor pollution sources. For instances, smoking, cooking,
incense, perfume or alcohol.
Filter reaches the end of life. Replace the lter with a new one.
The color of the air
quality light always
stays the same.
The particle sensor is dirty. Clean the particle sensor (see the chapter
“Cleaning and maintenance”).
The appliance produces
a strange smell.
The rst few times you use the appliance, it may produce a plastic smell.
This is normal. However, if the appliance produces a burnt smell even
if removing lters, contact your Philips dealer or an authorized Philips
service center. The lter may produce smell after being used for a while
because of the absorption of indoor gases. It’s recommended that you
reactivate the lter by putting it in direct sunlight for repeated use. If
odor still exists, replace the lter.
The appliance is extra
loud.
It's normal if the appliance runs at the Turbo mode.
In the Auto mode, if the appliance is too loud, maybe the appliance runs
at high speed because air quality becomes worse, or your personalized
setting in App triggers a higher fan speed. You can choose the Sleep
mode, or change the settings in the App.
If there is abnormal sound, contact the Consumer Care Center in your
country.
If anything drops into the air outlet, it may also cause abnormal loud
sound. Immediate turn o appliance, turn appliance upside down, to get
foreign objectives out of appliance.