Column Refrigeration Installation & Operation Manual
INSTALLATION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
PRIOR TO INSTALLATION
Before beginning installation,
carefully inspect the cabinet for hidden damage. If
damage is discovered, immediately le a claim with
the transportation company. Perlick is not responsible
for damage in transit.
When moving the unit, be sure to
protect nished ooring with appropriate material to
avoid damage from moving the appliance.
If the unit has been laid on its back
or sides, place unit upright and allow minimum of 24
hours before connecting the unit. Failure to do so can
aect the function and performance of the appliance.
This appliance should be installed
in dry, ventilated indoor location. The ambient
temperature of the location must be between 55°F
(13°C) and 100°F (43°C) for optimal performance.
This product must be installed on a
level oor for safety and optimal performance. The
base must be at to ensure anti-tip brackets properly
function and that the refrigeration system is level. Any
walls and surrounding furniture/xtures need to be
securely attached to the oor, wall studs or concrete
prior to installation of the column.
To ensure proper performance, the
air intake (toe kick) must not be blocked. Perlick
refrigeration is front-breathing — covering the intake
will cause the system to overheat and fail.
Perlick column doors open to 105°.
When installing a panel thicker than ¾” (19), or if
located next to adjacent wall, the 90° hinge stop pin
may be required to prevent damage to the unit and
adjacent cabinetry/walls. This hinge pin must be
installed prior to full integration.
In addition, the appliance must not be in direct
exposure of constant sunlight or excessive heat. If
it must be installed next to a heat source, such as a
cooking appliance or radiant heat, you must install an
insulating plate between the column and heat source.
When fully stocked, Perlick column refrigeration is
very heavy. To ensure the safety and prevent home
damage, the load-bearing capacity of your oor must
be 846 lbs (384 kg).
INSTALLATION TOOLS AND MATERIALS
▪ Screwdrivers (standard and #2 Phillips)
▪ Power drill
▪ Needle nose pliers
▪ Drill bits
▪ 13mm socket or wrench set
▪ 2’ and 4’ levels
▪ Material to protect ooring and
surrounding cabinetry
OPENING DIMENSIONS - SINGLE UNIT
The depth of each Perlick column is 24” (610).
Allow for panel thickness when planning the nished
opening depth. A minimum of a 4” (102) nished
return is required on all sides of the opening. See
page 6 for niche and product dimension drawings.
It is important that the side walls of the niche are
plumb prior to installation. The minimum thickness
of both the side walls and the top wall must be 5/8”
(16). A thickness of 3/4” (19) is recommended for
toe kick panels.
Framed cabinets will require additional nished
ller material behind the face frame for a proper
installation. Refer to the illustration on page 6.
OPENING DIMENSIONS - TWO UNITS
When installing two units side-by-side, a Perlick
Dual Installation Kit (part number CR-ACC-D1) is
required. You must plan for both units plus dual
installation kit when planning the cut-out dimensions.
The cutout width for a dual CR24 installation
is 48”. The cutout width for a dual installation
consisting of one CR24 and one CR30 is 54-
1/2”. For more information, see instructions that
accompany the CR-ACC-D1.