SAFETY & PRECAUTIONS
WARNING
For using R32 refrigerant
• Do not use means to accelerate the
defrosting process or to clean, other than
those recommended by the manufacturer.
• The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open ames, an
operating gas appliance or an operating
electric heater).
• Do not pierce or burn.
• Be aware that the refrigerants may not
contain an odor.
• Appliance should be installed, operated and
stored in a room with a oor area according
to the amount of refrigerant to be charged.
For specic information on the type of gas
and the amount, please refer to the relevant
label on the unit itself. When there are
dierences between the label and the manual
on the Min. room area description, the
description on label shall prevail.
• Appliance shall be installed, operated and
stored in a room with a oor area larger
than 43 sq. ft. (4 m
2
). Appliance shall not be
installed in an unventilated space, if that space
is smaller than 43 sq. ft. (4 m
2
).
• Any open re or device like switch which
may generate spark/arcing shall be around
appliance to avoid causing ignition of the
ammable refrigerant used. Please follow
the instructions carefully when storing
or maintaining the appliance to prevent
mechanical damage from occurring.
• Servicing should only be performed
as recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of the person competent in
the use of ammable refrigerants.
• DO NOT modify the length of the power cord
or use an extension cord to power the unit.
• DO NOT share a single outlet with other
electrical appliances. Improper power supply
can cause re or electrical shock. When
maintaining or disposing the appliance, the
refrigerant shall be recovered properly, shall
not discharge to air directly.
• Compliance with national gas regulations
shall be observed.
• Keep ventilation openings clear of obstruction.
• The appliance shall be stored so as to prevent
mechanical damage from occurring.
• A warning that the appliance shall be
stored in a well-ventilated area where the
room size corresponds to the room area
as specied for operation.
• Any person who is involved with working on
or breaking into a refrigerant circuit should
hold a current valid certicate from an
industry-accredited assessment authority,
which authorizes their competence to handle
refrigerants safely in accordance with an
industry recognized assessment specication.
All training shall follow the ANNEX HH
requirements of UL 60335-2-40 4th Edition
Examples for such working procedures are:
– breaking into the refrigerating circuit;
– opening of sealed components;
– opening of ventilated enclosures.